+86 15359293870 2804538582@qq.com
Industrial equipment parts procurement network

Kollmorgen AKD-P00306-NAAN-0000|Servo Drive Motor|

$9,549.00

In stock

Manufacturer:AKD-P00306-NAAN-0000

  • If interference occurs in the CNC, or the analog or digital path measurement systems, then there are some additional measures, listed below:
    additional ferrite rings on the motor leads
    wiring in armature chokes (please use the types supplied by us)
    HF filter on the CNC setpoint output (RC combination 1k/10nF)
    In each case you will have to try out which measures bring sufficient reduction in interference
  • AAll products on this website are discounted products, and market prices have been fluctuating. Please refer to customer service quotes for details. Pictures are not actual photos. Before placing an order, please confirm the model, product, price, and other detailed information with customer service. Both second-hand and brand new products are available for sale on this website. Please contact customer service for further communication.

 

  • If interference occurs in the CNC, or the analog or digital path measurement systems, then there are some additional measures, listed below:
    additional ferrite rings on the motor leads
    wiring in armature chokes (please use the types supplied by us)
    HF filter on the CNC setpoint output (RC combination 1k/10nF)
    In each case you will have to try out which measures bring sufficient reduction in interference

Kollmorgen AKD-P00306-NAAN-0000|Servo Drive Motor|

Kollmorgen AKD-P00306-NAAN-0000|Servo Drive Motor|illustration

  • Important instructions Inspect the nameplate of the controller. Check that the rated voltage and rated current match the transformer and motor data. Do not switch on the operating voltage before you have read Chapter II of this manual (Commissioning). Make sure that the maximum permissible rated voltage of 43V~ on terminals 20 , 22 , 32 is not exceeded. An excessive voltage on these terminals will destroy the ballast circuit in the controller. Make sure that the controller has sufficient ventilation : up to 8A rated current : vertical mounting, natural convection above 8A rated current : vertical mounting, additional fan, forced convection An incorrect mounting position or a missing fan for rated currents above 8A will lead to destruction of the controller.Ensure that the cables have an adequate cross-section, to avoid excessive losses and overheating in the cables. Use twisted cables for setpoint, tacho and motor cables. Tacho and setpoint cables must also be shielded. Observe the notes in Chapter II.2.1 . Earth the DC-link (Pin 28 or stud —GND/PE). A DC-link circuit which is not earthed can endanger the operator of the equipment, in the event of an earth short in the motor or fault currents in the GND lead. Furthermore,the electronics can be destroyed if the earth is missing when there is a fault. An earth short in the motor will no longer be recognised if the earth connection is missing. All earth connections must be led out from a common star point, to avoid earth loops and potential drops in the earth lead.Connect all earth leads to a PE busbar, for instance in the switchgear cabinet. Do not earth the tachometer cable, since one side of the tacho connection in the controller has a low-impedance connection to Analog-GND. Take care that the shielding is connected correctly : Tacho shielding to the controller (Pin 28/stud —GND/PE) or to the shielding connection terminal Setpoint shielding to CNC-GND on the controls (single ended) Motor cable shielding to the PE busbar, using a shielding terminal Loop the BTB contact (Pins 8bd or terminals 8,9) into the safety circuit of the system. Only so can you be sure that the controller-ready function is monitored. The ±15V auxiliary voltages must not be led out of the cabinet. This avoids capacitively or inductively induced interference. Chapter II Installation and Commissioning Page II – 1 Kollmorgen 12.99 Series 04S Warning Never connect or disconnect the transistor controller while the system is live. In unfavourable circumstances this could result in the destruction of the electronics. Capacitors can still have a residual charge up to 120 sec. after switching off the mains supply. Measure the voltage in the DC-link, and wait until it has fallen below 20V. Even when the motor is not rotating, control and power cables can still be live.

Kollmorgen AKD-P00306-NAAN-0000|Servo Drive Motor|

Kollmorgen AKD-P00306-NAAN-0000|Servo Drive Motor|illustration1

By structuring the information in this manner, the article provides a clear and organized understanding of input channels, transducer supply, and communication implementations in distributed control systems.

Zhangzhou Fengyun’s main products include ABB, GE, Bently Nevada Bentley, ICS TRIPLEX, Honeywell, Schneider, EPRO, yokogawa Yokogawa, Woodward, EMERSON, Emerson, and Invensys TRICONEX, which have abundant inventory, fast delivery, and reliable quality.

 



    Customers reviews

    There are no reviews yet.

    Be the first to review “Kollmorgen AKD-P00306-NAAN-0000|Servo Drive Motor|”

    Your email address will not be published. Required fields are marked *

    Search for products

    Back to Top
    Product has been added to your cart