All products on this website are discounted products, and market prices have been fluctuating. Please refer to customer service quotes for details. Pictures are not actual photos. Before placing an order, please confirm the model, product, price, and other detailed information with customer service. Both second-hand and brand new products are available for sale on this website. Please contact customer service for further communication.
ABB REF610|Feeder Protection Relay|

REF610
Output Contacts and Signal Routing
The relay is equipped with a comprehensive output interface consisting of:
Three power output contacts: PO1, PO2, and PO3
Two standard signal output contacts: SO1 and SO2
Three optional signal output contacts: SO3, SO4, and SO5
The relay uses switchgroups SGR1…SGR8 to provide flexible signal routing. These switchgroups allow internal signals from the following functions to be assigned to the required output contacts:
Protection stage operations
External trip signals
Automatic reclosing function signals
The output operation characteristics can be configured according to application requirements:
Minimum output pulse duration can be selected as 40 ms or 80 ms
Power output contacts can be configured as latched outputs for applications requiring maintained trip or alarm indications
This flexible output configuration allows the relay to adapt to various protection, control, and signaling schemes in substations and industrial power systems.
5.1.1.4 Disturbance Recorder
The relay incorporates an internal disturbance recorder for capturing and analyzing fault events and system disturbances.
The recorder can store:
Instantaneous measured signal values
RMS (Root Mean Square) curves of measured signals
Up to eight user-selectable digital signals
The digital signals available for recording include:
Digital input signals from external devices
Internal signals generated by protection functions and logic stages
Each selectable digital signal can be configured as a recording trigger based on:
Rising edge activation (signal changes from OFF to ON)
Falling edge activation (signal changes from ON to OFF)
The disturbance recorder provides valuable event analysis information for:
Protection operation verification
Fault investigation
System performance evaluation
Maintenance troubleshooting
5.1.1.5 Front Panel Interface
The relay front panel provides a local human-machine interface (HMI) for configuration, monitoring, and operation.
The front panel includes:
Display
2 × 16 character alphanumeric LCD
Backlight illumination
Automatic contrast adjustment for improved readability under different lighting conditions
LED Indicators
The relay provides:
Three fixed-function LEDs
Green LED
Yellow LED
Red LED
Eight programmable red LEDs
The programmable LEDs can be assigned to indicate user-defined conditions such as:
Protection trips
Alarms
Equipment status
Communication states
Control Buttons
The HMI keypad includes:
Four navigation arrow buttons
Clear/Cancel button
Enter button
These controls are used for:
Navigating through the relay menu structure
Viewing measurements and status information
Adjusting configuration parameters
Confirming setting changes
Communication Interface
The front panel includes:
Optically isolated serial communication port
Communication status indicator LED
The optical isolation provides improved electrical safety and immunity against interference in substation environments.
HMI Password Protection
The relay supports two levels of HMI password protection:
1. Main HMI Setting Password
Used to protect:
Protection settings
Control parameters
Configuration values
User-adjustable relay parameters
2. HMI Communication Password
Used specifically to protect:
Communication-related settings
Communication configuration parameters
Password protection prevents unauthorized modification of critical relay settings.
By default, both passwords are inactive. They become effective only after the default password has been replaced with a user-defined password.
Once activated, password entry is required before protected parameters can be modified.
Key Procurement / Engineering Considerations
Feature Engineering Benefit
Multiple power and signal outputs Supports flexible trip, alarm, and control schemes
Configurable SGR1…8 routing Simplifies relay logic customization without external wiring changes
Adjustable pulse duration Compatible with different breaker and control circuit requirements
Latched power outputs Enables maintained trip/alarm applications
Internal disturbance recorder Provides post-fault analysis capability
Programmable LEDs Improves local fault indication and diagnostics
Optical serial interface Enhances communication reliability and electrical isolation
Dual password levels Protects protection and communication parameters from unauthorized changes
ABB REF610|Feeder Protection Relay|
Hot selling models
ABB
5SHY3545L0009 3BHB013085R0001 3BHE009681R0101 GVC750BE101
5SHY3545L0010 3BHB013088R0001 3BHE009681R0101 GVC750BE101
5SHY3545L0014 3BHE023784 3BHE019719R0101 GVC736BE101
PM866A 3BSE076359R1
PM866AK01 3BSE076939R1
PM866K01 3BSE050198R1
PM876-1 3BDH000707R1
PPD513A0E110110 3BHE039724R0E41
PPD513AOC-100440 3BHE039724R0C3D 800 D513
PPD517A3011 3BHE041576R3011
PFEA112-20 3BSE030369R0020
PFEA112-20 3BSE050091R20
PFEA112-65 3BSE050091R65
PFEA113-20
AI815 3BSE052604R1
3BHE017628R0002 PPD115A02 SG579989013
3BHE019719R0101 GVC736BE101
3BHE022294R0103 GFD233A103
3BHE023784R1023 PP D113 B01-10-150000
5SHY4045L0001 3BHB018162R0001 3BHE009681R0101 GVC750BE101
5SHY4045L0003 3BHB021400 3BHE019719R0101 GVC736BE101
5SHY4045L0004 3BHB021400R0002 3BHE039203R0101 GVC736CE101
5SHY4045L0006 3BHB030310R0001
5SHY5055L0002 3BHE019719R0101 GVC736BE101
5SHY6545L0001 AC10272001R0101 5SXE10-0181
CI858-1 3BSE018137R1
CI858K01 3BSE018135R1
CI868K01-EA
CI873K01 3BSE058899R1
Recommended other models:
REF545KM133AAAB|Feeder Terminals|
REF545KC133AAAA|Feeder Terminals|
REF545KB133AAAA|Feeder Terminals|
REF542PLUS 1VCR007346|Protection Relay|
REF542PLUS 1VCF752000|Protection Relay|
REF542 1VCR007346 G0028|Protection Relay|
REF541KM115AAA|Protection Relay|
RED670|Line Differential Protection and Control|

✅ ABB
PP846 HMI Touch Screen, 5SHY Series IGCT, PM Series Controllers, AI/DO I/O Modules, SP Series Bailey Modules
✅ GE
VMIC, IS200 & IS215 Series CPU and Modules
✅ Emerson
Control Modules, EPRO Probes
✅ Westinghouse
1C Series Modules
✅ Honeywell
CC Series Modules
✅ Schneider
140 Series Modules
✅ Triconex
Full Series Safety Instrumented System Modules
✅ Bently
3500 Series Vibration Monitoring System
✅ Rexroth
Industrial Motors & Drives
✅ Foxboro
Compact Control Modules


-480x480.jpg)