All products on this website are discounted products, and market prices have been fluctuating. Please refer to customer service quotes for details. Pictures are not actual photos. Before placing an order, please confirm the model, product, price, and other detailed information with customer service. Both second-hand and brand new products are available for sale on this website. Please contact customer service for further communication.
TRICONEX 3301|Digital Input Module|

Core functionality
TMR Security Collection
Each input is collected in parallel by three independent circuits and output through 2oo3 voting. Single channel/single module faults do not affect the safe operation of the system and meet SIL 3 requirements.
Channel isolation and anti-interference
1500V AC isolation between channels effectively suppresses on-site surges and common mode interference, and is suitable for industrial strong electromagnetic environments.
Comprehensive diagnosis and status reporting
Real time monitoring of channel disconnection, short circuit, overvoltage/undervoltage, uploading fault information to the controller, supporting SOE recording and alarm, facilitating quick problem location.
Flexible signal adaptation
Compatible with dry contacts (such as emergency buttons, limit switches) and active 24V DC input, supports Sinking/Routing wiring, and is compatible with various field devices.
Hot swapping and online maintenance
During operation, it can be directly plugged and replaced without stopping the machine. It is configured with automatic synchronization to ensure the continuous operation of the system.
Application
Safety Instrumented System (SIS): ESD emergency shutdown, BMS burner management, F&G fire and gas detection, collecting emergency button, cut-off valve position, flame/gas detector status.
Process interlocking control: pump/compressor status in petrochemical, refining, LNG, high and low level switches in storage tanks, pressure/temperature over limit alarm.
Electricity/Energy: Overspeed, vibration, temperature switch signals for gas turbines/steam turbines, safety interlocks for power plant boilers.
Dangerous area: In conjunction with ATEX/IECEx certified racks, used for safety signal acquisition in explosion-proof zone 1/2.