All products on this website are discounted products, and market prices have been fluctuating. Please refer to customer service quotes for details. Pictures are not actual photos. Before placing an order, please confirm the model, product, price, and other detailed information with customer service. Both second-hand and brand new products are available for sale on this website. Please contact customer service for further communication.
GE 489-P5-LO-A20-E-H|Generator Management Relay|

Core Strengths
Comprehensive Generator Protection
Provides full-condition generator protection, including:
Stator differential protection
100% stator ground fault protection
Overexcitation protection
Loss of excitation (demagnetization)
Reverse power protection
Suitable for synchronous generators of various capacity levels, from industrial captive units to utility-scale generators
Accurate Condition Monitoring
Integrated 12 RTD inputs and 4 analog measurement channels
Real-time monitoring of stator temperature, bearing temperature, vibration, speed, and electrical parameters
Enables early fault detection and condition-based maintenance
Easy Maintenance & High Availability
Drawer-type modular design, allowing module replacement without system power-off
Independent H-module diagnostics, ensuring fast fault localization
Significantly reduces maintenance time and unplanned downtime
Flexible Communication & System Integration
Supports multiple communication protocols for local and remote monitoring
Easily integrates with SCADA systems, DCS platforms, and intelligent substation networks
Designed to meet modern digital power plant and substation communication requirements
Electrical & I/O Specifications
Rated Measurement Inputs
Current transformer (CT):
5 A phase CT secondary
Voltage transformer (VT):
System voltage configurable
RTD inputs:
12 channels (stator and bearing temperature measurement)
Voltage inputs:
4-channel VT voltage input
Digital I/O
Digital inputs:
7 configurable digital input channels
Relay outputs:
6 × Form-C relay outputs
Includes H-module hardwired trip circuits for high-speed fault isolation
Analog I/O
Analog inputs:
4-channel isolated 4–20 mA inputs (vibration, speed, auxiliary signals)
Analog outputs:
4-channel isolated 4–20 mA outputs (control commands and signal transmission)
Communication Interfaces
Maintenance interface:
RS-232 local maintenance port
Serial communication:
2 × RS-485 (supports Modbus RTU and DNP3.0)
Ethernet:
10Base-T Ethernet
Supports Modbus TCP
Typical Application Scenarios
Power Plants / Captive Power Plants
Acts as the main generator protection device, providing differential, overcurrent, overvoltage, and excitation-related protections
The H module enables rapid tripping during severe faults
Seamlessly interfaces with DCS and SCADA systems
Key Industrial Power Systems
Used in petrochemical, metallurgical, and other industrial sectors with on-site power generation
H-module architecture meets high-reliability and safety requirements, preventing fault propagation and production losses
Substations
Protects grid-connected synchronous generators
Supports fast fault clearance and continuous monitoring of generator and grid operating parameters
GE 489-P5-LO-A20-E-H|Generator Management Relay|

By structuring the information in this manner, the article provides a clear and organized understanding of input channels, transducer supply, and communication implementations in distributed control systems.
Zhangzhou Fengyun’s main products include ABB, GE, Bently Nevada Bentley, ICS TRIPLEX, Honeywell, Schneider, EPRO, yokogawa Yokogawa, Woodward, EMERSON, Emerson, and Invensys TRICONEX, which have abundant inventory, fast delivery, and reliable quality.



There are no reviews yet.